ACR / Nauticast™ Technical Information
Default MMSI Settings
We have received reports from some administrations who monitor Class A AIS messages that some of the ACR
/ Nauticast AIS systems transmit a default MMSI (1193046).
Causes
User fails to enter an MMSI when system is installed.
MMSI reverts to default value when external power is lost and
the internal memory backup battery becomes discharged.
Corrective Actions
Users are reminded to check operation of their AIS to assure that
an MMSI has been correctly installed in the AIS.
Users can check for condition of memory backup battery periodically as follows:
With AIS powered up, check that proper MMSI is entered into the AIS system.
Remove power from the AIS system for approximately 2 minutes.
Apply power to the system and check that the correct MMSI is present.
If step 3) shows default MMSI (1193046), the memory backup battery is probably discharged and must
be serviced.
AIS TRANSPONDERS
How to Check and Change your MMSI Numbers.
Select from the Main Menu “Service Configuration”. Menu is SERVICE password protected with default
password “NAUT”. Enter your Service Password when prompted. Use the up and down arrows on keypad to
select “Change MMSI / IMO” than press M5 “Select” or “by pressing number 3 on the keypad.
Input your MMSI number and press Save to store data. The unit will reboot itself after pressing Save.
Power unit off and on and verify that the unit reboots with the correct MMSI. If not, see step 4 above.